The 5-star luxury GD Victoria Hotel by the Grupo Fedola on the Costa Adeje is in one of the most prestigious tourist regions of Tenerife and is spectacularly impressive with its 1000 m² of steep pitched green roof – among the steepest of its kind in Europe.  Colourful, drought-resistant flowering plants rise up on both sides of the building and along all seven storeys. As this project is having such an impact on the entire green roof world far beyond the Canary Islands, it has received the Green Roof Influenceraward.

It is a five-minute walk to the strand from the GF Victoria Hotel, which is named after its managing director, Victoria López, and was designed by the architects Javier Álvarez and Silvia de Miguel. The hotel speaks the language of extravagance, both inside and out: 242 luxury suites with terraces and a sea view, in addition to exclusive wellness and spa areas both indoors and on the expansive roof terrace. Green roof areas play a vital role in the overall architecture and are a true testimony to the ecological focus of the building.

Steep pitched green roof: Shear protection is decisive

The ZinCo system build-up “Steep Pitched Green Roof” with Georaster® is perfect for steep roofs with a pitch of up to 35°. Given that some of the roof pitches in the GF Victoria Hotel are even steeper than that, more intensive measures were required for shear protection. For this reason, more than 700 ZinCo Shear-Fix LF 300 elements in combination with Eaves Profiles TRP 80 were installed on the root-resistant roof waterproof membrane. In this way, dense rows of shear barriers were created across the entire width of the roof, and Protection Mat WSM 150 and the Georaster® elements were subsequently installed between them. The Georaster® elements, approx. 54 x 54 cm in size and 10 cm high, are interlocked without the need for tools, and they immediately create a stable structure. Their low volume provides for a comparatively large space for root penetration. The better the root-penetration of the subsequent plants, the lower the risk of erosion.

The Georaster® elements were infilled with a locally produced substrate to a depth of 12 cm. The mineral part of the substrate is lava from the volcanic island of Tenerife and the organic component is a compost mixture of green cuttings and locally occurring mash.

Additional erosion prevention measures

Prior to planting, the substrate layer was secured against wind and water erosion using an organic, biodegradable adhesive in addition to coconut fibre nets. Following this, it is essential to plant as quickly and as far-reaching as possible as gaps in the vegetation could in turn mark the start of erosion. Pre-cultivated vegetation mats are generally used for greening steep pitched roofs. In this case we chose the planting option. A well-developed root system and a particularly high plant density were important for planting. Mainly endemic plants were chosen, that is to say, plant types that are indigenous to the Canary Islands and that are best adapted to the climate there. Plants from other warm regions were also used, all of which are heat-resistant and require less water. Two synchronised irrigation systems with driplines in conjunction with the ZinCo Protection Mat WSM 150 provide not only for a perfect supply of water but also the lowest possible level of water consumption.

Green Roof Influencer

The steep pitched green roofs are in full bloom, lending the GF Victoria Hotel a unique and striking appearance. This is the result of the committed collaboration of everyone involved in the project in meeting the significant technical challenges posed by greening the steep pitched roofs of the hotel. For this reason, Gerardo Machado, Managing Director of the contractors, Impermeabilizaciones Machado, S.L.U., was awarded the “Green Roof Influencer” prize.

Author: Fabian Kaiser, Head of International Sales, ZinCo GmbH

Photos: ZinCo GmbH / Impermeabilizaciones Machado, S.L.U.

Site board:

Construction project:
Hotel GF Victoria, 38679 Costa Adeje, Santa Cruz de Tenerife, Spain
Client:
GF Hoteles, Grupo Fedola group of companies, 38002 Santa Cruz de Tenerife, Spain
Construction year:
2017
Roof area:
approx. 1000 m²
Green roof build-up:
ZinCo system build-up “Steep Pitched Green Roof” with Georaster®
Architect:
Javier Álvarez and Silvia de Miguel, Santa Cruz de Tenerife, Spain
Execution:
Impermeabilizaciones Machado, S.L.U., 38300 La Orotava, Santa Cruz de Tenerife, Spain
System supplier:
ZinCo Cubiertas Ecológicas S.L., 28001 Madrid, Spain

For further information, please contact:

ZinCo GmbH
Lise-Meitner-Straße 2
72622 Nürtingen
Germany
Tel.: +49 7022 6003-0
Fax: +49 7022 6003-100
Email: info@zinco-greenroof.com
www.zinco.de and www.zinco-greenroof.com

and

ZinCo Cubiertas Ecológicas S.L.
C/ Velázquez 15, 1° Derecha
28001 Madrid
Spain
Tel.: +34 910 059 175
Mobile: +34 608 262 503
Email: contacto@zinco-iberica.es
www.zinco-cubiertas-ecologicas.es

 

 

Firmenkontakt und Herausgeber der Meldung:

ZinCo GmbH
Lise-Meitner-Str. 2
72622 Nürtingen
Telefon: +49 (7022) 6003-0
Telefax: +49 (7022) 6003-100
http://www.zinco-greenroof.com

Ansprechpartner:
Pressekontakt
ZinCo GmbH
Telefon: +49 (7022) 6003-0
Fax: +49 (7022) 6003-100
E-Mail: info@zinco-greenroof.com
Für die oben stehende Pressemitteilung ist allein der jeweils angegebene Herausgeber (siehe Firmenkontakt oben) verantwortlich. Dieser ist in der Regel auch Urheber des Pressetextes, sowie der angehängten Bild-, Ton-, Video-, Medien- und Informationsmaterialien. Die United News Network GmbH übernimmt keine Haftung für die Korrektheit oder Vollständigkeit der dargestellten Meldung. Auch bei Übertragungsfehlern oder anderen Störungen haftet sie nur im Fall von Vorsatz oder grober Fahrlässigkeit. Die Nutzung von hier archivierten Informationen zur Eigeninformation und redaktionellen Weiterverarbeitung ist in der Regel kostenfrei. Bitte klären Sie vor einer Weiterverwendung urheberrechtliche Fragen mit dem angegebenen Herausgeber. Eine systematische Speicherung dieser Daten sowie die Verwendung auch von Teilen dieses Datenbankwerks sind nur mit schriftlicher Genehmigung durch die United News Network GmbH gestattet.

counterpixel